Three Phase Portable Energy Meter Calibration Equipment




Features :

  • Reference standard and power source integrated
  • Accuracy class 0.05
  • 0-20A/0-500V, 0-120A/0-500V
  • Start testing and creep testing
  • Test by automatic or manual
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection
  • 7 inch TFT touch screen
  • Weight light 15Kg


Electrical Parameters 

Accuracy class  0.05%, 0.1%
Power supply One Phase AC 100-265V, frequency 50/60Hz.
AC Current output
Range (I1, I2, I3 ) 200mA, 1A, 5A, 20A, 100A(optional)
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 30VA
Accuracy 0.05%RG
AC Voltage output
Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional)
Adjustment range (0-120)%RG(1)
Adjust fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load each phase 30VA
Measuring accuracy 0.05%RG
Phase Output
Output adjustment range 0o-359.999o
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01o
Accuracy 0.03o
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 10, 1, 0.1, 0.01 as optional.
Measurement accuracy 0.0005
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V,10mA

Environmental Conditions

Ambient Temperature -10oC to +50oC
Relative Humidity 35%-85%
  • RG means range, the same as below;
  • RD means the set harmonic content, harmonic can be a single output, also multiple output.

Mechanical Parameters

Dimensions (W×D×H) (mm) 495x390x195
Weight (kg) 15

Product Ordering Guide

No. Accuracy Voltage range Current range Weight
302D112001 0.001 0-500V 0-120A 22KG
302D1120005 0.0005 0-500V 0-120A 22KG
302D11201 0.001 0-500V 0-12A 15KG
302D112005 0.0005 0-500V 0-12A 15KG
302D12401 0.001 0-500V 0-24A 16KG
302D124005 0.0005 0-500V 0-24A 16KG


Contact Us

Myriad Industrial Solutions LLP

A-401, Vini Garden, Mandapeshwar Road, Dahisar, West Mumbai, Maharashtra - 400068, India

Call Us : 08042753938